Flintglas® Mineral Surfaced Cap CoolStar™



 


view larger image

Flintglas® Mineral Surfaced Cap w/CoolStar™

CertainTeed Flintglas Mineral Surfaced Cap Sheet CoolStar is a roll roofing product designed for use as a cap sheet over inorganic and organic built-up roofing systems. It is surfaced with ceramic granules and an acrylic-based CoolStar coating to provide a durable, heat reflective weathering surface when used as a cap sheet. Flintglas Mineral Surfaced Cap Sheet CoolStar has initial ratings for solar reflectance of 0.77 and thermal emittance of 0.92 from the Cool Roof Rating Council (CRRC). It also exceeds initial ENERGY STAR® and California Title 24 Standards.

Easy to Install...the CoolStar coating is factory applied by CertainTeed, so there is no need for post-installation, on-site coating. Installing a CoolStar-coated roof surface product is a one-step process, and touch-up can occur immediately after.

This roofing product qualifies for an energy tax credit of up to $1500 under the American Recovery and Reinvestment Act. For more information, visit the CertainTeed Energy Tax Credit page.
CertainTeed Flintglas Mineral Surfaced Cap Sheet CoolStar is manufactured on a durable, high quality fiber glass mat which receives a heavy coating of weathering grade asphalt and is surfaced with ceramic granules and an acrylic-based CoolStar coating. The fiber glass base mat provides excellent strength and moisture resistance in conjunction with a reflective, durable granule surface.

Flintglas Mineral Surfaced Cap Sheet CoolStar has an initial rating from the Cool Roof Rating Council (CRRC) for solar reflectance at 0.77 and thermal emittance of 0.92.


  • Support Mat: Wet process fiber glass mat
  • Surfacing: Ceramic granules and flexible, acrylic-based CoolStar Coating
  • Weight: 83 lbs. per roll
  • Dimensions: 39-3/8" x 32' 10" (108 sq. ft.)
  • Coverage: One square
  • Thickness: 3.0mm (120 mils)


  • For additional technical resources please refer to the CertainTeed Commercial Roof Systems Manual or click on the Technical Information link located on the left navigation area.

CertainTeed Finagles Mineral Surfaced Cap Sheet CoolStar may be applied in either hot asphalt or approved cold adhesive such as CertainTeed''''''''''''''''''''''''''''''''s FlintBond™. Rolls should be stored upright, off ground, completely protected from the weather. Roof decks shall be structurally sound, dry, smooth and meet or exceed minimum requirements of the deck manufacturer, local code and CertainTeed. Roof decks shall provide positive drainage.

For detailed installation instructions please refer to the CertainTeed Commercial Roof Systems Manual or click on the Installation Instructions link located on the left navigation area.
Outstanding Warranty Options

CertainTeed backs its commercial roofing systems with the confidence of three warranty choices:

Limited Product Warranty
NDL Roof Membrane Limited Warranty*
Integrity Coverage Warranty*

Owners and specifiers who choose the NDL or Integrity Coverage warranty options have the added security of manufacturer involvement in the sometimes difficult process of contractor qualifying and workmanship inspection. Consult with the roofing contractor and your CertainTeed commercial roofing territory manager to decide which CertainTeed warranty is best for your building or project.

*NDL and Integrity Coverage (IC) warranties are not available on all specifications and are only available through CertainTeed Golden and Silver Star Contractors. (IC is only available through CertainTeed Golden Star Contractors.)

CoolStar exceeds initial ENERGY STAR® and California Title 24 standards.


CoolStar-coated roofing products are more energy-efficient than standard roofing products and exceed initial ENERGY STAR standards.


To meet ENERGY STAR standards, a low slope roofing surface must have a solar reflectivity of .65 (meaning it reflects 65% of the radiation away from the surface and absorbs 35%).


In general, an ENERGY STAR-labeled product can help reduce energy costs by at least 30%.


The state of California has an even tougher requirement for a "cool" or energy-saving roof called Title24.  To comply, a low slope roofing surface must have an initial solar reflectivity of .70 and thermal emittance of .75.  CoolStar-coated roofing products surpass both of these important, industry-recognized standards.


All CoolStar cap sheets have initial ratings for solar reflectance and thermal emittance from the Cool Roof Rating Council (CRRC).