HT Blanket (High Temperature Blanket)



Flexible and resilient thermal insulation

view larger image
Basic Uses

HT Types 1 and 2 are designed for use on industrial equipment operating at temperatures up to 1000°F (538°C). Type 1 can be used on panel systems, as a flexible wrap or on industrial ovens. Type 2 can be used for metal mesh blankets and on boilers, vessels and other industrial equipment operating at temperatures up to 1000°F (538°C).

Product Description

High Temperature Blanket is composed of rotary glass fibres bonded together using a thermosetting resin and formed into plan, flexible and resilient insulation.

Features and Benefits
• Can be used on industrial equipment operating at temperatures up to 1000°F (538°C).
• May be applied directly to any hot surface.
• Type 1 can be used on panel systems as a flexible wrap, or on industrial ovens.
• Type 2 can be used for metal mesh blankets, on boilers, vessels and other industrial equipment operating at temperatures up to 1000°F (538°C).
• Type 1 is available in batt or roll form.
• Type 2 is available in batt form only.
• Easy to handle, cut with a knife and install.
• Contains over 60% recycled glass content.

Bacterial and fungi resistance:
-ASTM C1338-96
-Does not breed or promote


Odor emission:
-ASTM C1304
-Pass test

Smoulder resistance:
-ULC-S129
-Mean mass loss 5% and each specimen ≤ 10%

Surface burning characteristics:
-ASTM E84/UL 723
-CAN/ULC-S102-M88
-Flame spread index: 25 max
-Smoke developed index: 50 max

Hot surface performance:
-ASTM C411
-Pass test at 1000ºF (538ºC), 8" stack

Density:
-Type 1: 1.25lb/ft3 (nominal) 20kg/m3
-Type 2: 2.5lb/ft3 (nominal) 40kg/m3

Thermal conductivity:

-ASTM C177
-Avg. K at 75ºF mean BTU · in/(hr · ft2 · ºF)

HT blanket insulations,  both Type 1 and Type 2, may be applied directly to any hot surface. This is normally accomplished by securing through the use of welded studs and nuts or pins and speed washers and then providing a final covering of sheet metal, expanded metal, metal mesh, or cemtentitous mastics. If pins and speed washers are incorporated, you must ensure that the insulation is not compressed under the washer.